Screw Type Water Cooled Chillers
Basic Info
Model No.: EKSC250
Product Description
Model NO.: EKSC250 Certification: ISO Function: Cooling, Heating and Heat Recovery Usage: for Air Conditioner HS Code: 841861900 Type: Water-Cooled Condition: New Cooling Capacity Range: 271kw-3492.4kw Origin: Guangdong Province Screw type water cooled chillers Features:
1. Heating capacity range: 77.6rt ~ 713.1rt (273kw~2508.2kw)
2. Cooling capacity range: 77rt ~ 993rt (271kw~3492.4kw)
3. Heating recovery range: 85.6rt ~ 580rt (301.5~2040kw)
4. Refrigerant: 134a or R22
EKSC series screw-type water cooled chillers feature a leading-edge screw unit design, inherit this air conditioning innovations over 40 years and integrate 13 patents. Equipped with a double screw compressor and a high-efficiency heat exchanger developed by us, the units work at the optimal efficiency with the help of a state-of-the-art control system. Thanks to an innovative condensate heat recovery technology, the units can be used for multiple purposes to save energy, and best apply to places that have mangy buildings and require central air conditioning and hot water systems, such as high-rank hotels, office buildings, schools, hospitals and factories.
Contact us if you need more details on Screw Type. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Cooled Chillers、Air Conditioner. If these products fail to match your need, please contact us and we would like to provide relevant information.
1. Heating capacity range: 77.6rt ~ 713.1rt (273kw~2508.2kw)
2. Cooling capacity range: 77rt ~ 993rt (271kw~3492.4kw)
3. Heating recovery range: 85.6rt ~ 580rt (301.5~2040kw)
4. Refrigerant: 134a or R22
EKSC series screw-type water cooled chillers feature a leading-edge screw unit design, inherit this air conditioning innovations over 40 years and integrate 13 patents. Equipped with a double screw compressor and a high-efficiency heat exchanger developed by us, the units work at the optimal efficiency with the help of a state-of-the-art control system. Thanks to an innovative condensate heat recovery technology, the units can be used for multiple purposes to save energy, and best apply to places that have mangy buildings and require central air conditioning and hot water systems, such as high-rank hotels, office buildings, schools, hospitals and factories.
Screw type water cooled chillers | ||||||||||||
Model No. | EKSC250 | EKSC280 | EKSC330 | EKSC400 | EKSC450 | EKSC500 | EKSC560 | EKSC660 | EKSC800 | EKSC900 | ||
Cooling | Cooling Capacity | U.S.RT | 248.5 | 280.6 | 331.8 | 403.5 | 448.8 | 496.9 | 561.3 | 663.5 | 806.9 | 897.6 |
KW | 873.8 | 987 | 1166.9 | 1419 | 1578.4 | 1747.6 | 1974 | 2333.7 | 2837.9 | 3156.8 | ||
Power Input | KW | 153.3 | 170.6 | 200.6 | 244.5 | 271.5 | 306.5 | 341.2 | 401.2 | 489 | 543 | |
COP | kw/kw | 5.7 | 5.79 | 5.82 | 5.8 | 5.81 | 5.7 | 5.79 | 5.82 | 5.8 | 5.81 | |
Chilled water flow | m³/h | 150.3 | 169.8 | 200.7 | 244.1 | 271.5 | 300.6 | 339.5 | 401.4 | 488.1 | 543 | |
Pressure drop of chilled water | kPa | 42 | 42 | 49 | 55 | 57 | 62 | 67 | 69 | 72 | 72 | |
Cooling Water flow | m³/h | 176.7 | 199.1 | 235.2 | 286.1 | 318.2 | 353.3 | 398.2 | 470.4 | 572.2 | 636.4 | |
Pressure drop of cooling water | kPa | 47 | 47 | 59 | 67 | 77 | 82 | 82 | 82 | 85 | 85 | |
Heating | Heating Capacity | U.S.RT | 347.8 | 392.3 | 462.4 | 562.4 | 625.4 | 695.6 | 784.5 | 924.9 | 1124.9 | 1250.7 |
KW | 1223.2 | 1379.6 | 1626.4 | 1978.1 | 2199.4 | 2446.4 | 2759.2 | 3252.8 | 3956.2 | 4398.8 | ||
Power Input | KW | 197.1 | 220.1 | 259.2 | 315.3 | 350.6 | 394.2 | 440.2 | 518.4 | 630.6 | 701.2 | |
COP | kw/kw | 6.21 | 6.27 | 6.27 | 6.27 | 6.27 | 6.21 | 6.27 | 6.27 | 6.27 | 6.27 | |
Hot water flow rate | m³/h | 150.3 | 169.5 | 199.8 | 243 | 270.2 | 300.6 | 339 | 399.6 | 486 | 540.4 | |
Pressure drop of Hot water | kPa | 34 | 34 | 43 | 48 | 56 | 59 | 59 | 59 | 61 | 61 | |
Water source flow rate | m³/h | 176.5 | 199.4 | 235.2 | 286 | 318 | 353 | 398.9 | 470.3 | 572 | 636 | |
Pressure drop of water source | kPa | 58 | 58 | 67 | 76 | 78 | 82 | 87 | 89 | 90 | 90 | |
Compressor | Type | Semi-closed double-screw compressor | ||||||||||
Qty | Set | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | |
Startup type | Y-# | |||||||||||
Power Supply | v/ph/hz | 380/3/50 | ||||||||||
Condenser | Type | Water cooled shell-tube type | ||||||||||
Qty | Set | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | |
Evaporator | Type | Flooded type | ||||||||||
Qty | Set | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Refrigerant | Type | R134a | ||||||||||
Lubricant | Code | EK03 | ||||||||||
Filling | L | 50 | 55 | 55 | 60 | 60 | 100 | 110 | 110 | 120 | 120 | |
Temperature control | PID control over water temperature | |||||||||||
Outer diameter of chilled water inlet/outlet pipe | diameter mm | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | |
Outer diameter of cooling water inlet/outlet pipe | diameter mm | 168.3 | 168.3 | 168.3 | 168.3 | 168.3 | 219.1 | 219.1 | 219.1 | 219.1 | 219.1 | |
Weight of a single indoor unit | kg | 5050 | 5250 | 5350 | 5450 | 5600 | 9510 | 9900 | 10070 | 10270 | 10580 | |
Operating Weight | kg | 5480 | 5680 | 5780 | 5880 | 6050 | 10250 | 10650 | 10810 | 11010 | 11310 | |
Rated current (cooling) | A | 263 | 293 | 345 | 420 | 466 | 526 | 586 | 689 | 840 | 933 | |
Rated current (heating) | A | 335 | 376 | 443 | 538 | 598 | 670 | 752 | 886 | 1076 | 1196 | |
Startup current | A | 749 | 882 | 1358 | 1358 | 1388 | 749 | 882 | 1358 | 1358 | 1388 | |
Max startup current (cooling) | A | 749 | 882 | 1358 | 1358 | 1388 | 1012 | 1175 | 1702 | 1778 | 1854 | |
Max startup current (heating) | A | 749 | 882 | 1358 | 1358 | 1388 | 1347 | 1551 | 2145 | 2316 | 2452 | |
Note: | ||||||||||||
1.Working conditions for nominal cooling capacity: inlet/outlet water temperature in the evaporator:12/7 degree; inlet/outlet water temperature in the condenser 30/35 degree | ||||||||||||
2. Working conditions for nominal heating capacity: water flow in the above table;inlet/outlet water temperature in the condenser:40/~ degree;inlet/outlet water temperature in the evaporator 20/~ degree (note:antifreeze is required when water temperature in the water circuit is lower than 3 degree in winter) | ||||||||||||
3. The pressure drop of condenser and evaporator don't include resistence from external water pipes and parts. | ||||||||||||
4. For on-site electric wiring,see the nameplate or installation manual of the unit | ||||||||||||
Product Categories : Water Chiller
Premium Related Products
Other Products
Hot Products
Horizontal Concealed Fan Coil UnitScrew Type Air Cooled Chiller (heat pump)Evi Air Source Heat Pump in Cold RegionsSwimming Pool Heat Pump for Heating and CoolingMultifunction Air Source Heat Pump (for Low Temperature area)Water Heat Pump Heating and CoolingNew product! R410a R134a rotary dehumidifier compressorDC Solar power 48v/60v mobile refrigeration freezer air cooling system KITSAUTO aircon compressor for EV RV traveling truck caravan grab excavator cabHVAC dc 12/12v R134a Cab of truck mining machine crane grab excavator camping car air conditioning system parts12/24vdc compressor for Mobile refrigerator motive freezer car fridgessupermarket display freezers cold storage of HVAC Refrigeration & Heat Exchange Equipment compressorHVAC R404A gas Refrigeration equipment Condensing Units for blood freezers cooling van supermarkets cateringCommercial cube ice making machine for beverage or drink cheap refrigeration unit Freezer for Ice Cream Ice cream compressortruck roof air conditioner accessories lanhai rv compressors for motorhome air conditioned compressor casement air conditionerHVAC solar power R134A DC 12v/24v/72v Speed variable compressor for EV RV truck sleeper cab tractor forklift