Find Water Chiller, Aquarium Chiller, Arcadia Brand Chiller on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Water Chiller > Screw Type Water Cooled Chillers

Screw Type Water Cooled Chillers

Basic Info

Model No.:  EKSC250

Product Description

Model NO.: EKSC250 Certification: ISO Function: Cooling, Heating and Heat Recovery Usage: for Air Conditioner HS Code: 841861900 Type: Water-Cooled Condition: New Cooling Capacity Range: 271kw-3492.4kw Origin: Guangdong Province Screw type water cooled chillers Features:

1. Heating capacity range: 77.6rt ~ 713.1rt (273kw~2508.2kw)
2. Cooling capacity range: 77rt ~ 993rt (271kw~3492.4kw)
3. Heating recovery range: 85.6rt ~ 580rt (301.5~2040kw)
4. Refrigerant: 134a or R22

EKSC series screw-type water cooled chillers feature a leading-edge screw unit design, inherit this air conditioning innovations over 40 years and integrate 13 patents. Equipped with a double screw compressor and a high-efficiency heat exchanger developed by us, the units work at the optimal efficiency with the help of a state-of-the-art control system. Thanks to an innovative condensate heat recovery technology, the units can be used for multiple purposes to save energy, and best apply to places that have mangy buildings and require central air conditioning and hot water systems, such as high-rank hotels, office buildings, schools, hospitals and factories.

 
Screw Type Water Cooled Chillers
Screw Type Water Cooled Chillers
Screw type water cooled chillers            
Model No.   EKSC250 EKSC280 EKSC330 EKSC400 EKSC450 EKSC500 EKSC560 EKSC660 EKSC800 EKSC900
Cooling Cooling Capacity U.S.RT 248.5 280.6 331.8 403.5 448.8 496.9 561.3 663.5 806.9 897.6
KW 873.8 987 1166.9 1419 1578.4 1747.6 1974 2333.7 2837.9 3156.8
 Power Input KW 153.3 170.6 200.6 244.5 271.5 306.5 341.2 401.2 489 543
COP kw/kw 5.7 5.79 5.82 5.8 5.81 5.7 5.79 5.82 5.8 5.81
Chilled water flow m³/h 150.3 169.8 200.7 244.1 271.5 300.6 339.5 401.4 488.1 543
Pressure drop of chilled water kPa 42 42 49 55 57 62 67 69 72 72
Cooling Water flow  m³/h 176.7 199.1 235.2 286.1 318.2 353.3 398.2 470.4 572.2 636.4
Pressure drop of cooling water kPa 47 47 59 67 77 82 82 82 85 85
Heating Heating Capacity U.S.RT 347.8 392.3 462.4 562.4 625.4 695.6 784.5 924.9 1124.9 1250.7
KW 1223.2 1379.6 1626.4 1978.1 2199.4 2446.4 2759.2 3252.8 3956.2 4398.8
 Power Input KW 197.1 220.1 259.2 315.3 350.6 394.2 440.2 518.4 630.6 701.2
COP kw/kw 6.21 6.27 6.27 6.27 6.27 6.21 6.27 6.27 6.27 6.27
Hot water flow rate m³/h 150.3 169.5 199.8 243 270.2 300.6 339 399.6 486 540.4
Pressure drop of Hot water  kPa 34 34 43 48 56 59 59 59 61 61
Water source flow rate m³/h 176.5 199.4 235.2 286 318 353 398.9 470.3 572 636
Pressure drop of  water source kPa 58 58 67 76 78 82 87 89 90 90
Compressor Type   Semi-closed double-screw compressor
Qty Set 1 1 1 1 1 2 2 2 2 2
Startup type   Y-#
Power Supply v/ph/hz 380/3/50
Condenser Type   Water cooled shell-tube type
Qty Set 1 1 1 1 1 2 2 2 2 2
Evaporator Type   Flooded type
Qty Set 1 1 1 1 1 1 1 1 1 1
Refrigerant Type   R134a
Lubricant Code   EK03
Filling L 50 55 55 60 60 100 110 110 120 120
Temperature control   PID control over water temperature
Outer diameter of chilled water inlet/outlet pipe diameter mm 219.1 219.1 219.1 219.1 219.1 219.1 219.1 219.1 219.1 219.1
Outer diameter of cooling water inlet/outlet pipe diameter  mm 168.3 168.3 168.3 168.3 168.3 219.1 219.1 219.1 219.1 219.1
Weight of a single indoor unit kg 5050 5250 5350 5450 5600 9510 9900 10070 10270 10580
Operating Weight  kg 5480 5680 5780 5880 6050 10250 10650 10810 11010 11310
Rated current (cooling) A 263 293 345 420 466 526 586 689 840 933
Rated current (heating) A 335 376 443 538 598 670 752 886 1076 1196
Startup current A 749 882 1358 1358 1388 749 882 1358 1358 1388
Max startup current (cooling) A 749 882 1358 1358 1388 1012 1175 1702 1778 1854
Max startup current (heating) A 749 882 1358 1358 1388 1347 1551 2145 2316 2452
                         
Note:                        
1.Working conditions for nominal cooling capacity: inlet/outlet water temperature in the evaporator:12/7 degree; inlet/outlet water temperature in the condenser 30/35 degree
2. Working conditions for nominal heating capacity: water flow in the above table;inlet/outlet water temperature in the condenser:40/~ degree;inlet/outlet water temperature in the evaporator 20/~ degree (note:antifreeze is required when water temperature in the water circuit is lower than 3 degree in winter)
3. The pressure drop of condenser and evaporator don't include resistence from external water pipes and parts.
4. For on-site electric wiring,see the nameplate or installation manual of the unit
                         

Contact us if you need more details on Screw Type. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Cooled Chillers、Air Conditioner. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Water Chiller